Skip to main content

perivox KOMB 3-2-3 schwarz

The perivox® KOMB Cat + DMX + Power is a flexible combination cable for indoor use that combines 3x Cat-7 data, 2x DMX/control, and Power 3x 2.5mm² in one cable. This allows data transmission, control signals, and power supply to be realized with just one cable run – ideal for media, event, and conference technology, studios, and fixed installations. Multi-stage shielding ensures interference-free signals while the overall cable construction is practically dimensioned.   Advantages:
  • combined functions
  • efficient installation
  • space-saving
  • high flexibility
  • interference-free transmission
PV217124000
ROHS
REACH
CE
UKCA
Article number PV217124000
Number of cores 4
Cross section 0.14 mm²
Conductor colour wh, bu
Core insulation pericel®
Jacket insulation perivin®
Jacket colour black
conductor stranded wire, bare copper – oxygen free / stranded wire, tin plated copper / stranded wire, bare copper
construction 26AWG single wire Ø 0,16mm / 26AWG
core insulation perimer® / pericel®
core diameter 0,98mm / 1,10mm / 3,00mm
number of cores 24 / 4 / 3
core colour wh, bu
wrapping foil / fleece
screening Aluminum laminated polyester film / Spiral shield tpc. opt.cov.98% single wire 0,10mm
jaket isolation perivin® / peripur®
jaket colour black
outer diameter 6,20mm / 3,00mm / 8,10mm / 20,50mm
testing voltage core/core 1.000V AC / 3.000V AC
testing voltage core/screen 500V AC
phase-to-phase voltage 300V AC
static temperature range -20 to 60°C
dynamic temperature range 0 to 50°C
static bending radius 6,0 x outer diameter
dynamic bending radius 8,0 x outer diameter
thermal load 6.950 kj/m
total weight 458,00 kg/1.000m
printing (white or black) perivox – Cat.7 AWG26/7 – PUR-H – Nr 1 – 3 / perivox – DMX 2×0,14mm² digital 110 Ohm – Nr. 1-2 / perivox – Power 3×2,5mm²
use Flexible combination cable. Using the cable in a different way than recommended in the specification, it may cause a reduction of safeness and/or a reduction of estimated durability of the cable. A utilization beyond the described and specified application is not provided. In case of any questions regarding the described applications, please contact team Multimedia. However, installation and processing must only be executed by qualified electricians.